I think option D.

for LIFO we need to check max time of Loading and for LRU min time of reference.
1
1
Yes but given is A i dont know how!
0
0
how is page 1 loaded at 280 and last referenced at 256 ?
0
0

1 Answer

0 votes
0 votes
Best answer

In LIFO, the page which has been loaded at last will be selected for the replacement

Here, its page 1 since it has the maximum loading time

In LRU, the page the has been referenced longest time in the past will be selected for the replacement.

Here, its page 1 since it has minimum time of reference that means it has referenced before all the pages.

So option D